products

Products

SMTH-D35 SMT 300 to 1000MHz Surface Mount Circulator

 


  • 300 to 1000MHz Surface Mount Circulator Features:
  • Good temperature stability:
  • Withstand high power:
  • RoHS compliant:
  • Weight: ≈ 55g
  • 300 to 1000MHz Surface Mount Circulator Material list:
  • Shell: industrial pure iron silvered
  • Inner conductor: silver plated brass
  • Product Detail

    Product Tags

    300 to 1000MHz Surface Mount Circulator Order Examples

    1

    300 to 1000MHz Surface Mount Circulator Basic Specifications

    Impedance 50 Ω
    Size(mm) Φ35.0*10.5
    Operating Temp -40~+85℃
    Storage temperature -50~+90 ℃
    ConnectorType SMT

    300 to 1000MHz Surface Mount Circulator Specifications

    Model No.

    (X=1: →Clockwise)

    (X=2: ←Anticlockwise)

    Freq. Range

    MHz

    IL.

    dB (max)

    Isolation

    dB (min)

    VSWR

     Power

    CW

    SMTH-D35-X/300-320MHz

    300-320

    0.60

    20.0

    1.25

    300

    SMTH-D35-X/300-350MHz

    300-350

    0.80

    18.0

    1.35

    300

    SMTH-D35-X/309-339MHz

    309-339

    0.50

    20.0

    1.25

    300

    SMTH-D35X-X/310-340MHz

    310-340

    0.50

    20.0

    1.25

    300

    SMTH-D35-X/320-340MHz

    320-340

    0.45

    20.0

    1.25

    300

    SMTH-D35-X/350-370MHz

    350-370

    0.40

    20.0

    1.25

    300

    SMTH-D35-X/350-400MHz

    350-400

    0.50

    19.0

    1.25

    300

    SMTH-D35-X/361-366MHz

    361-366

    0.30

    23.0

    1.20

    300

    SMTH-D35-X/370-420MHz

    370-420

    0.50

    19.0

    1.25

    300

    SMTH-D35-X/380-410MHz

    380-410

    0.40

    20.0

    1.25

    300

    SMTH-D35-X/380-460MHz

    380-460

    0.50

    18.0

    1.30

    300

    SMTH-D35-X/390-410MHz

    390-410

    0.30

    23.0

    1.20

    300

    SMTH-D35-X/400-410MHz

    400-410

    0.30

    23.0

    1.20

    300

    SMTH-D35-X/400-440MHz

    400-440

    0.40

    20.0

    1.25

    300

    SMTH-D35-X/400-450MHz

    400-450

    0.40

    20.0

    1.25

    300

    SMTH-D35-X/400-470MHz

    400-470

    0.40

    20.0

    1.25

    300

    SMTH-D35-X/400-500MHz

    400-500

    0.50

    19.0

    1.25

    300

    SMTH-D35-X/410-460MHz

    410-460

    0.40

    20.0

    1.25

    300

    SMTH-D35-X/413-419MHz

    413-419

    0.30

    25.0

    1.15

    300

    SMTH-D35-X/419-425MHz

    419-425

    0.30

    25.0

    1.15

    300

    SMTH-D35-X/420-450MHz

    420-450

    0.40

    20.0

    1.25

    300

    SMTH-D35-X/420-480MHz

    420-480

    0.40

    20.0

    1.25

    300

    SMTH-D35-X/425-475MHz

    425-475

    0.40

    20.0

    1.25

    300

    SMTH-D35-X/429-439MHz

    429-439

    0.30

    25.0

    1.15

    300

    SMTH-D35-X/430-440MHz

    430-440

    0.30

    23.0

    1.20

    300

    SMTH-D35-X/430-460MHz

    430-460

    0.40

    20.0

    1.25

    300

    SMTH-D35-X/430-470MHz

    430-470

    0.40

    20.0

    1.25

    300

    SMTH-D35-X/433-457MHz

    433-457

    0.30

    23.0

    1.20

    300

    SMTH-D35-X/435-437MHz

    435-437

    0.30

    23.0

    1.20

    300

    SMTH-D35-X/440-470MHz

    440-470

    0.30

    23.0

    1.20

    300

    SMTH-D35-X/447-499MHz

    447-499

    0.30

    23.0

    1.20

    300

    SMTH-D35-X/450-456MHz

    450-456

    0.30

    25.0

    1.15

    300

    SMTH-D35-X/450-500MHz

    450-500

    0.40

    20.0

    1.25

    300

    SMTH-D35-X/450-520MHz

    450-520

    0.40

    20.0

    1.25

    300

    SMTH-D35-X/450-550MHz

    450-550

    0.40

    20.0

    1.25

    300

    SMTH-D35-X/455-465MHz

    455-465

    0.30

    25.0

    1.15

    300

    SMTH-D35-X/459-486MHz

    459-486

    0.30

    23.0

    1.20

    300

    SMTH-D35-X/470-490MHz

    470-490

    0.30

    20.0

    1.20

    300

    SMTH-D35-X/470-530MHz

    470-530

    0.40

    20.0

    1.20

    300

    SMTH-D35-X/470-570MHz

    470-570

    0.40

    20.0

    1.25

    300

    SMTH-D35-X/470-610MHz

    470-610

    0.50

    18.0

    1.30

    300

    SMTH-D35-X/475-525MHz

    475-525

    0.30

    23.0

    1.20

    300

    SMTH-D35-X/495-516MHz

    495-516

    0.30

    23.0

    1.20

    300

    SMTH-D35-X/500-600MHz

    500-600

    0.40

    20.0

    1.20

    300

    SMTH-D35-X/500-700MHz

    500-700

    0.70

    17.5

    1.35

    300

    SMTH-D35-X/570-670MHz

    570-670

    0.30

    23.0

    1.20

    300

    SMTH-D35-X/580-720MHz

    580-720

    0.45

    20.0

    1.25

    300

    SMTH-D35-X/600-700MHz

    600-700

    0.40

    20.0

    1.25

    300

    SMTH-D35-X/670-770MHz

    670-770

    0.30

    23.0

    1.20

    300

    SMTH-D35-X/690-860MHz

    690-860

    0.40

    20.0

    1.20

    300

    SMTH-D35-X/700-862MHz

    700-862

    0.50

    18.0

    1.30

    300

    SMTH-D35-X/700-900MHz

    700-900

    0.50

    18.0

    1.30

    300

    SMTH-D35-X/703-862MHz

    703-862

    0.40

    20.0

    1.25

    300

    SMTH-D35-X/750-950MHz

    750-950

    0.50

    18.0

    1.30

    300

    SMTH-D35-X/770-860MHz

    770-860

    0.30

    23.0

    1.20

    300

    SMTH-D35-X/600-800MHz

    600-800

    0.50

    18.0

    1.30

    300

    SMTH-D35-X/700-1000MHz

    700-1000

    0.60

    16.0

    1.40

    300

    SMTH-D35-X/750-950MHz

    750-950

    0.40

    20.0

    1.25

    300

    SMTH-D35-X/800-1000MHz

    800-1000

    0.40

    20.0

    1.25

    300

    SMTH-D35-X/854-921MHz

    854-921

    0.30

    20.0

    1.20

    300

    SMTH-D35-X/860-872MHz

    860-872

    0.25

    25.0

    1.15

    300

    SMTH-D35-X/862-960MHz

    862-960

    0.30

    25.0

    1.20

    300

    SMTH-D35-X/900-930MHz

    900-930

    0.25

    25.0

    1.15

    300

    SMTH-D35-X/900-1000MHz

    900-1000

    0.40

    20.0

    1.25

    300

     

    Instructions:

     

    1, When the surface mount circulator adopts reflow welding process, the maximum temperature does not exceed 260 degrees;

    2, The circulator only provides through power, indicating that the transmission to the antenna and the antenna to the receiving are through power;

    3, Only some common frequencies in the table, can be produced according to the user's requirements;

    4, If you do not find what you are looking for, please contact us!


  • Previous: